diff options
author | Yevgeny Kliteynik <kliteyn@nvidia.com> | 2021-12-12 16:19:58 +0200 |
---|---|---|
committer | Saeed Mahameed <saeedm@nvidia.com> | 2021-12-22 20:38:46 -0800 |
commit | 624bf42c2e3930acca9fcfc340b2fa38e712da84 (patch) | |
tree | c8dd683768d25f7bc5df9dee63fe97ab658c12d3 | |
parent | 6b8b42585886c59a008015083282aae434349094 (diff) | |
download | slab-624bf42c2e3930acca9fcfc340b2fa38e712da84.tar.gz |
net/mlx5: DR, Fix querying eswitch manager vport for ECPF
On BlueField the E-Switch manager is the ECPF (vport 0xFFFE), but when
querying capabilities of ECPF eswitch manager, need to query vport 0
with other_vport = 0.
Fixes: 9091b821aaa4 ("net/mlx5: DR, Handle eswitch manager and uplink vports separately")
Signed-off-by: Yevgeny Kliteynik <kliteyn@nvidia.com>
Reviewed-by: Alex Vesker <valex@nvidia.com>
Signed-off-by: Saeed Mahameed <saeedm@nvidia.com>
-rw-r--r-- | drivers/net/ethernet/mellanox/mlx5/core/steering/dr_domain.c | 4 |
1 files changed, 1 insertions, 3 deletions
diff --git a/drivers/net/ethernet/mellanox/mlx5/core/steering/dr_domain.c b/drivers/net/ethernet/mellanox/mlx5/core/steering/dr_domain.c index f6e6d920976613..c54cc45f63dc36 100644 --- a/drivers/net/ethernet/mellanox/mlx5/core/steering/dr_domain.c +++ b/drivers/net/ethernet/mellanox/mlx5/core/steering/dr_domain.c @@ -164,9 +164,7 @@ static int dr_domain_query_vport(struct mlx5dr_domain *dmn, static int dr_domain_query_esw_mngr(struct mlx5dr_domain *dmn) { - return dr_domain_query_vport(dmn, - dmn->info.caps.is_ecpf ? MLX5_VPORT_ECPF : 0, - false, + return dr_domain_query_vport(dmn, 0, false, &dmn->info.caps.vports.esw_manager_caps); } |