aboutsummaryrefslogtreecommitdiffstats
path: root/Documentation/hwmon
diff options
context:
space:
mode:
authorLeonard Anderweit <leonard.anderweit@gmail.com>2022-12-18 12:31:31 +0100
committerGuenter Roeck <linux@roeck-us.net>2023-02-03 07:30:09 -0800
commit2c55211104b44bd1b83009f0af204237a62e28bd (patch)
tree5df38bc36ef5eaac30ebbd71fe5872a8989cfd73 /Documentation/hwmon
parent1ed5036b3be7db1b694bcaa4095869bdb8657d49 (diff)
downloadlinux-2c55211104b44bd1b83009f0af204237a62e28bd.tar.gz
hwmon: (aquacomputer_d5next) Support sensors for Aquacomputer Aquaero
Add support for reading sensors of the Aquacomputer Aquaero 5/6 fan controllers. These fan controllers supports 4 fans, 8 physical temperature sensors, 8 virtual temperature sensors and 2 flow sensors. Temperature and flow sensor reading implemented by Aleksa Savic [1] [2] [3]. [1] https://github.com/aleksamagicka/aquacomputer_d5next-hwmon/pull/31 [2] https://github.com/aleksamagicka/aquacomputer_d5next-hwmon/pull/51 [3] https://github.com/aleksamagicka/aquacomputer_d5next-hwmon/pull/55 Originally-from: Aleksa Savic <savicaleksa83@gmail.com> Signed-off-by: Leonard Anderweit <leonard.anderweit@gmail.com> Link: https://lore.kernel.org/r/20221218113131.3752-7-leonard.anderweit@gmail.com Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Diffstat (limited to 'Documentation/hwmon')
-rw-r--r--Documentation/hwmon/aquacomputer_d5next.rst5
1 files changed, 5 insertions, 0 deletions
diff --git a/Documentation/hwmon/aquacomputer_d5next.rst b/Documentation/hwmon/aquacomputer_d5next.rst
index 637bdbc8fcad43..b94ff08080bfa7 100644
--- a/Documentation/hwmon/aquacomputer_d5next.rst
+++ b/Documentation/hwmon/aquacomputer_d5next.rst
@@ -5,6 +5,7 @@ Kernel driver aquacomputer-d5next
Supported devices:
+* Aquacomputer Aquaero 5/6 fan controllers
* Aquacomputer D5 Next watercooling pump
* Aquacomputer Farbwerk RGB controller
* Aquacomputer Farbwerk 360 RGB controller
@@ -20,6 +21,10 @@ Description
This driver exposes hardware sensors of listed Aquacomputer devices, which
communicate through proprietary USB HID protocols.
+The Aquaero devices expose eight temperature sensors, eight virtual temperature
+sensors and two flow senors. The fans expose their speed (in RPM), power,
+voltage and current.
+
For the D5 Next pump, available sensors are pump and fan speed, power, voltage
and current, as well as coolant temperature and eight virtual temp sensors. Also
available through debugfs are the serial number, firmware version and power-on