Kernel driver vt7505

Supported chips:

Author: Georgi Vlaev <gvlaev@juniper.net>

Description

This driver supports hardware monitoring for the Analog Devices MAX16545 and MAX16550, and the Volterra VT7505 PMBus controllers.

The devices report input and output voltage, input and output current, input power, and temperature. All values use the PMBus direct data format. Peak (maximum) values for input voltage, output voltage, output current, input power and temperature are exposed and can be reset. Writing to any *_reset_history attribute clears all of the device’s peak values.

The reported current and power values depend on the resistance of the external current-report resistor connected between the ILOAD pin and ground. This resistance can be provided via the adi,rload-ohms device tree property; a default of 4750 ohms is used when it is absent.

Sysfs entries

The limit and alarm attributes are created by the PMBus core for the limit registers that the device implements. See Naming and data format standards for sysfs files for the meaning of each attribute.

in1_label

“vin”

in1_input

Measured input voltage.

in1_min

Input undervoltage warning limit.

in1_min_alarm

Input undervoltage warning alarm.

in1_lcrit

Input undervoltage fault limit.

in1_lcrit_alarm

Input undervoltage fault alarm.

in1_highest

Historical maximum input voltage.

in1_reset_history

Write to reset all peak values.

in2_label

“vout1”

in2_input

Measured output voltage.

in2_min

Output undervoltage warning limit.

in2_min_alarm

Output undervoltage warning alarm.

in2_highest

Historical maximum output voltage.

in2_reset_history

Write to reset all peak values.

curr1_label

“iin”

curr1_input

Measured input current.

curr1_alarm

Input current alarm.

curr2_label

“iout1”

curr2_input

Measured output current.

curr2_max

Output overcurrent warning limit.

curr2_max_alarm

Output overcurrent warning alarm.

curr2_highest

Historical maximum output current.

curr2_reset_history

Write to reset all peak values.

power1_label

“pin”

power1_input

Measured input power.

power1_max

Input overpower warning limit.

power1_alarm

Input overpower warning alarm.

power1_input_highest

Historical maximum input power.

power1_reset_history

Write to reset all peak values.

temp1_input

Measured temperature.

temp1_max

Overtemperature warning limit.

temp1_max_alarm

Overtemperature warning alarm.

temp1_crit

Overtemperature fault limit.

temp1_crit_alarm

Overtemperature fault alarm.

temp1_highest

Historical maximum temperature.

temp1_reset_history

Write to reset all peak values.