# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause) %YAML 1.2 --- $id: http://devicetree.org/schemas/hwmon/pwm-fan.yaml# $schema: http://devicetree.org/meta-schemas/core.yaml# title: Fan connected to PWM lines maintainers: - Jean Delvare - Guenter Roeck properties: compatible: const: pwm-fan cooling-levels: description: PWM duty cycle values corresponding to thermal cooling states. $ref: /schemas/types.yaml#/definitions/uint32-array items: maximum: 255 fan-supply: description: Phandle to the regulator that provides power to the fan. interrupts: description: This contains an interrupt specifier for each fan tachometer output connected to an interrupt source. The output signal must generate a defined number of interrupts per fan revolution, which require that it must be self resetting edge interrupts. maxItems: 1 fan-shutdown-percent: description: Fan RPM in percent set during shutdown. This is used to keep the fan running at fixed RPM after the kernel shut down, which is useful on hardware that does keep heating itself even after the kernel did shut down, for example from some sort of management core. minimum: 0 maximum: 100 fan-stop-to-start-percent: description: Minimum fan RPM in percent to start when stopped. minimum: 0 maximum: 100 fan-stop-to-start-us: description: Time to wait in microseconds after start when stopped. pulses-per-revolution: description: Define the number of pulses per fan revolution for each tachometer input as an integer. $ref: /schemas/types.yaml#/definitions/uint32 minimum: 1 maximum: 4 default: 2 pwms: description: The PWM that is used to control the fan. maxItems: 1 "#cooling-cells": true required: - compatible - pwms additionalProperties: false examples: - | pwm-fan { compatible = "pwm-fan"; cooling-levels = <0 102 170 230>; pwms = <&pwm 0 10000 0>; #cooling-cells = <2>; }; thermal-zones { cpu_thermal: cpu-thermal { thermal-sensors = <&tmu 0>; polling-delay-passive = <0>; polling-delay = <0>; trips { cpu_alert1: cpu-alert1 { temperature = <100000>; /* millicelsius */ hysteresis = <2000>; /* millicelsius */ type = "passive"; }; }; cooling-maps { map0 { trip = <&cpu_alert1>; cooling-device = <&fan0 0 1>; }; }; }; }; - | #include pwm-fan { compatible = "pwm-fan"; pwms = <&pwm 0 40000 0>; fan-supply = <®_fan>; interrupt-parent = <&gpio5>; interrupts = <1 IRQ_TYPE_EDGE_FALLING>; pulses-per-revolution = <2>; };